InteliSENS® SLR mini Series
Speed & Length Measurement
The InteliSENS® SLRmini non-contact speed and length measurement gauge is ideal for flat surface products in “roll to roll” or “cut to length” processes. Paper, Film, Foil, Wovens, Non-Wovens, Textiles, Roofing, Sidings, Gypsum Board are just a few examples. Applications where speed measurement is critical for drive control or where length measurement is critical for product quality will benefit from the increased accuracy of Laser Doppler Speed and Length Measurement.
Get the Proton MDIS App
- No Slip, No Wear, No Marking of your product
- No Moving Parts, Increased Reliability and MTBF
- Incredibly small and easy to install
- Pulse outputs like your encoder
- Digital Communications you need
- Stand Alone Measuring Device or Fully Integrated to PLC
- Zero Speed and Automatic Direction Detection
Performance
SLRmini 1220 | SLRmini 3060 | |
Stand Off Distance | 120mm 4.74” | 300mm 11.81” |
Depth of Field | 20mm 0.79” | 60mm 2.36” |
Minimum Speed | 0 m/min 0 ft/min | 0 m/min 0 /ft/min |
Maximum Speed | + - 2000 m/min + - 6562 ft/min | + - 5000 m/min + - 16404 ft/min |
Accuracy
Factory Calibrated to better than 0.05% within the central 20% of the Depth of Field.
Repeatability of 0.02%
Measurement
Maximum Acceleration Rate of 1000m/s2 (3280ft/s2)
Measurement Rate Up to 50,000/sec (20us)
Units
Speed Measurement selectable m/min, ft/min, yd/min
Length Measurement selectable m, ft, inch, yd
Material Present
For part length measurement
Zero Speed
The SLRmini Series gauges can detect true zero speed as the product comes to stop
Direction Detection
Automatic Direction Detection is ideal if you product rewinds, relaxes when stopped or has vibration in the stopped condition. The SLRmini Series of gauges will cancel forward reverse movements to maintain zero speed and length.
Connectivity
RS422 Differential Pair Pulse Outputs Configurable as Quadrature or Index
Default Output 5vdc or User Input to 24vdc Max
2MHz Max Pulse Output Rate
Non Isolated, Normally Open (High State) Pulldown Logic Inputs
Maximum Voltage: +/-30V Minimum Current 3mA
Reverse Direction, Length Hold, Display Hold, Speed Hold, Total Length
Reset, End of Reel / Batch Length Reset
Maximum Voltage 25Vdc Current 0.1A
Gauge Ok, Object Detected, Gauge Measuring, Good Readings Low,
Gauge Temperature High, Preset Length 1, Preset Length 2
RS232 Modbus Communications
USB using RS232 - USB Converter Cable
ZM4000 Printer Communications
Connects to Proton Products CDi4 Display
Connect to a PC or Mobile Device and use the Proton Products Gauge
App available for iOS and Android. Ideal for gauge configuration and
diagnostics.
Ethernet TCP/IP Modbus is the Default Communication. Connect to a PLC using optional ProfiBus, ProfiNet, EtherNet I/P or DeviceNet.
Laser Doppler
Class 3B Visible Laser.
Wavelength 650 - 670 nm, typically 658 nm with a beam diameter of 3mm (0.12”)
Total emitted power 40mW. Power Density at Stand Off Distance 1120mW/cm2
Electrical and Operating Requirements
Power Supply
15 - 28 Vdc
Power Consumption
15 Watts
Operating Temperature
5°C - 40°C (41°F-104°F)*
*See Accessories for High-Temperature protection options
Environmental Protection
IP 67
Size and Weight
Height
142mm (5.6”)
Width
104mm (4.1”)
Thickness
53mm (2.1”)
Weight
3kg (6.6lbs)